Overview of the types and characteristics of gas boilers Neva lux


Description of the gas wall-mounted boiler Neva Lux 8224

Double-circuit gas wall-mounted boiler Neva Lux 8224 with a closed combustion chamber is intended for apartment heating and hot water supply in multi-storey buildings, as well as in private suburban areas up to 240 m².

Security

Gas wall-mounted boiler Neva Lux 8224 absolutely safe to use. The manufacturers have provided for all possible emergency situations. The gas supply to the boiler is automatically stopped when the burner flame goes out, the heating medium heats up to a temperature of more than 90 ° C, irregularities and problems in the smoke exhaust system, power outages, and also when the pressure drops below the maximum permissible level.

Built-in functions of anti-freezing, automatic protection against blocking of the pump, "acidification" of the three-code valve. If the pressure in the heating system rises above 3 bar, the coolant is discharged.

In the event of a malfunction, an electronic self-diagnosis system displays error codes on the display.

Separate heat exchanger system

The gas boilers Neva Lux 8224 have two heat exchangers: a copper one for the heating circuit and a secondary stainless steel plate heat exchanger for hot water supply. In practice, this means that hot water supply and heating are less dependent on each other than when operating boilers with a bithermal heat exchanger. In addition, boilers with separate heat exchangers are less demanding on water quality.

The use of a system of two separate heat exchangers can significantly reduce the likelihood of scale formation in the primary heat exchanger, thereby reducing service costs and extending the life of the device.

Additional features

Everyone who wants to buy a gas boiler Neva Lux 8224 can choose the options he needs: connecting an outside temperature sensor, room thermostat, indirect heating boiler, remote control, etc.

Features of the gas wall-mounted boiler Neva Lux 8224

  • Continuous electronic flame modulation
  • Gas type: natural or liquefied
  • Electronic control
  • Multilevel security system
  • Secondary plate heat exchanger
  • Temperature accuracy up to 1 ° C
  • Automatic electronic ignition
  • Electronic self-diagnosis system
  • LCD display

Source: mrklimat.ru

Gas heating equipment of the company Neva Lux is used to maintain a comfortable temperature in industrial premises, in apartment buildings, in private houses and household structures. Gas boilers are the development of Russian designers; the equipment has been in operation for more than a year by municipal enterprises. All devices of the Neva Lux company operate on main gas, but there are also models that operate on the basis of liquefied gas. Read about the advantages of gas boilers Beretta on this page.

Technical characteristics of gas boilers Neva

Gas boilers Neva deluxe are distinguished by an affordable price. The designers of the company took into account the conditions in which the Neva Lux boilers are forced to work.

  • The equipment can continue to operate even with liquid and gas pressure differences in the system.
  • Almost all models are equipped with a copper heat exchanger, which is launched only on the heating circuit.
  • When assembling the Neva Lux gas boiler, components made in Europe are used.
  • All units have a multi-level security system and a progressive design that can compete with gas boilers and Beretta.
  • Some of the models can function even with fluctuating ambient temperatures.
  • Domestic heating device has a high level of efficiency -96-98%.

Types of gas boilers Neva

On the heating equipment market in Russia, the following variations of gas heating boilers Neva luxury wall-mounted type with two circuits are provided:

  1. boiler Neva deluxe 7218 - a gas boiler designed to heat a room with an area of ​​180 sq.m., you can heat both a private house and apartments in a multi-storey building;
  2. gas boiler Neva lux 7224 - a budget option Neva lux 8224. It has the same functionality, has a bithermal heat exchanger. Designed for heating an apartment building;
  3. wall-mounted gas boiler Neva deluxe 8224 is a gas boiler designed for apartment heating of a multi-storey building. Also, the device is designed to heat liquid for household needs of the consumer. It can also be used to heat a private type S room of 240 sq. M .;
  4. wall-mounted gas boiler Neva lux 8618 - the most progressive model Neva lux, characterized by low energy consumption;
  5. gas hot water boiler Neva - boiler equipment of this type is combined, operates at a power of 10.5 -24 kW, operates at a constant temperature;
  6. gas wall-mounted boiler Neva Tranzit NT 24 - is intended for heating liquid for household needs of the consumer and heating small premises.

Installation and connection of Neva boilers

Before connecting the heating device, it is necessary to draw a project diagram in accordance with which the device will be inserted into the system. The diagram will further serve as the basis for the repair of the heating system or the boiler itself. It is also necessary to take into account that the installation and connection of the equipment should be carried out by a specialist with sufficient knowledge and experience. How to install Buderus gas boilers, read here: https://teplamore.com/kotly/gazovye/obzor-vidov-gazovyx-kotelov-buderus.html

Neva luxury boiler, instruction manual

In accordance with the completeness of the Neva Lux gas boiler, together with the device itself, there is a warranty card, fasteners and operating instructions in the package. It contains all possible variants of breakdowns, methods of connecting the device to the heating system and much, much more. From the point of view of specialists, there is nothing complicated in operating a heater. All issues are completely solvable on their own. The only thing that should be taken into account is that if the equipment breaks down, it will be necessary to call a specialist, otherwise, if the user tries to repair the device on his own, he risks harming not only himself, but also the premises, as well as his loved ones. Gas is a dangerous, explosive material that, if handled incorrectly, can lead to irreparable consequences.

Gas boiler Neva lux, malfunctions

Any equipment can fail, gas boilers are no exception. For example, the most common malfunctions that occur with this boiler:

  • Low gas level in the system;
  • Extinction of the flame;
  • Low pressure in the heating system;
  • Malfunctions from physical impact.

If something fails, then you need to contact the technical support service. It is not worth solving the problem on your own, because the guarantee is valid only if the integrity of the device is not violated, which is impossible with self-repair.

Price for gas heating boilers Neva Lux

Heating equipment can be purchased at a fairly affordable price, because the equipment is designed for the middle class, i.e. on the general population of the Russian Federation. All heaters of gas type Neva Lux are in the price range from 12,000 rubles to 32,000 rubles.

Where to buy a gas boiler Neva Lux?

You can purchase equipment for the heating system both directly at the company's sales offices and in specialized trade organizations selling heating equipment and sanitary ware.

You can buy a gas boiler Neva Lux in Moscow at the following addresses:

  1. Moscow city. Severodvinskaya 13 to 1 Contact phone number,
  2. Moscow, Belorechenskaya st., 37, building 1 Contact phone
  3. Moscow, st. Govorova d. 16, building 6. Contact phone

You can buy a gas boiler Neva Lux in St. Petersburg at the following addresses:

  1. Office "Techno Dom" St. Petersburg, Stachek ave., 57 Contact phone
  2. St. Petersburg, B. Sampsonievsky prospect, 92 Contact phone, 8 (812) 670-21-25
  3. LLC "Proteplo" St. Petersburg, Chugunnaya, house 14, lit. K (entrance from Mendeleevskaya 9) Contact phone, 8 800 775-63-03

Video

Watch a video presentation of one of the Neva luxury boilers below:

By purchasing Neva Lux heating equipment, the consumer receives not only a comfortable atmosphere in his home, but also a durable "partner", as well as quality and reliability. Gas boilers Neva luxury, among other things, are still quite a democratic option for large country houses and small country houses. Which of the gas boilers Navien to choose, read on this page.

Source: teplamore.com

History of the Neva company

Russian users are well aware of the Neva Lux single-circuit and double-circuit wall-mounted gas boiler. But not everyone knows that a company that produces such equipment appeared on the market more than 50 years ago.

The original enterprise was called Gazapparat. It specialized in the production of any gas equipment, including columns, boilers, heaters. Currently, the company belongs to the largest concern Baltic Gas Company.

Thanks to this alliance, such models as Neva Lux and a new product on the market - the Turbo model, appeared. Deficiencies in the work of the first models were taken into account and were eliminated in subsequent ones. As a result, the consumer receives a product of European quality.

Specifications


Wall-hung gas double-circuit boilers Neva Lux

Various modifications of gas boilers Neva Lux are suitable for heating homes, industrial and office buildings. Their modifications heat rooms with different areas. High reliability and "smart" automation brought these boilers to a leading position among Russian manufacturers.

Specifications:

  • Thanks to the powerful gas supply pump, they can work in low pressure systems. The pump itself will create the necessary conditions, depending on the settings.
  • Copper heat exchangers have higher efficiency than cast iron and steel models.
  • All major movements are made in Italy. Localization of production is limited to the manufacture of the body and unimportant parts. Cooperation with foreign partners, the use of European technologies has a beneficial effect on the quality and economy of the product.
  • Foreign technologies provide 100% security.
  • Easily adapt to specific operating conditions.
  • The efficiency reaches 98%.

Thanks to the cooperation of European manufacturers, the consumer is provided with a technological and reliable device of high quality.

Lineup of gas boilers Neva

The units manufactured by Neva are subdivided into two series: Lux and Turbo. Devices belonging to the Lux series are divided into two categories:

  1. Single-circuit wall-mounted gas boiler Neva Lux. Designed only to supply the house with heat. If you connect an indirect heating boiler, then such a unit will be able to provide the house with hot water supply.Due to the fact that a modulating burner is included in the package of the device, which can change the intensity of combustion based on a given temperature regime, the device is highly economical. Boiler operation can be converted to liquefied gas. Gas single-circuit wall-mounted boilers Neva have found a wide demand from users also due to their low price, simple maintenance, as well as the absence of volatile nodes that are subject to voltage drops in the network.
  2. Double-circuit wall gas boiler Neva Lux. These devices have open and closed combustion chambers, as well as a bithermal heat exchanger. The chimney can be either coaxial or traditional. The process of heating the coolant is controlled by highly accurate automation. The maximum distortion from a given temperature regime is no more than 1%. Another key difference between a double-circuit wall-mounted gas boiler is the ability to connect two heating systems at once. There are outlets for underfloor heating.

If you connect a thermostat, you will significantly reduce gas consumption and the automation will function completely independently. The control unit will automatically adjust the heating of the coolant based on how warm it is in the room.

Boilers Neva Lux - Repair and maintenance

___________________________________________________________________________________________

  • Errors of the Neva Lux boiler and their meanings

The gas wall-mounted boiler Neva Lux 8224 (BaltGaz) is in operation. Starting it up, I found out that the burner did not start. Before the start-up, on the new, just purchased, the following measures were taken: Mounted jets for liquefied gas; A jumper is installed to operate on this fuel; It was reprogrammed. If you hold down the "Reset" button until the moment when the "little man" lights up, you can start it. He has a good flame - a normal blue color. The heating system is working properly, warm water is supplied to both the radiators and the warm floor. In summer mode, when the DHW is started, it also does not want to work. It ignites the gas and immediately goes out, and so on several times. It starts working only after manipulating the reset button. That is, the problem is observed in both summer and winter modes. Confused - entry and exit, because they could not figure out the designations on. But I have a water gun installed, and so it shouldn't be a problem. Why can there be problems like me? I have a system of three gas cylinders installed, which are connected to each other by a hose through tees and through reducers. I did not check the gas supply pressure. Logically, even if there is a malfunction somewhere, the pressure of the remaining cylinders should compensate for the missing one. The simplest reducer is a frog for gas cylinders. Will different gas supply pressures affect combustion? If, before, then how? The jets were delivered according to the technical instructions. When reprogramming to work with liquefied gas, only the ignition power was changed. The jumper is installed correctly. Where to look for the problem? Faced a similar problem on NevaLux and didn't have enough experience to solve the problem myself. But in fact, everything is simple there. When new nozzles were installed, it was necessary to dismantle the flame sensors (metal contacts in white ceramic insulation). So it was these contacts that turned away from the flame during installation and stopped seeing it. The unit received a signal that there was no flame, and there was a constant ignition. The problem was discovered by a specialist from the service center, by checking all contacts one by one. This may be a design defect and occurs on all models. The specialist, so that I do not lose the warranty, made a note in the service book about the presence of such a problem. I cannot solve problems with fine tuning and adjusting parameters through the remote control - neva lux on the baltgaz 7224 gas boiler. The manual assures that it is possible to control the temperature maintenance mode parameter by modulating the flame or by turning the device on and off.However, when I enter the menu, in the parameter "P01", the temperature scale appears, instead of "0" - turning the device on and off and "1" - flame modulation. Tell me, what then is the program for fine tuning the boiler? What is written in the instructions does not correspond to reality. P1- means the power supplied by the ignition (for smooth operation). P2 - heating power. It is exposed based on the size of the heated room. I have a house of 48 sq. m. To heat it, I bought and installed a Neva Lux 8618 wall-mounted boiler. I chose this particular model, since in the future I plan to increase the heated area to 90 sq. m. m. The heating system consists of 6 aluminum batteries with six sections (total power 6912 W). Recently I read in the instructions that for the installation it is necessary to take into account its characteristics and the characteristics of the heating network. For this model, the minimum heat transfer should be at least 8.9, and mine is 2 kW less. Is this critical, or will I be able to work through the winter like this, and solve the problem in the summer? I just do not like the phrase from the instructions about the instability of work and a decrease in the service life. Nothing bad will happen. However, you will need to connect a room thermostat and make additional settings. Take the most common thermostat, working on / off principle, no need to take the programmable one. But keep in mind that the numbers on the spinner do not always correspond to the truth. Two years ago, I installed a gas boiler Neva Lux 7224 at my home. The connection was organized through IBPS-12-350K Sibkontakt. It already has the third board, now it's neva pcb rev7. The first fell into disrepair during a thunderstorm. The R65 unit is faulty on both boards. Now the new boards have become expensive and I thought about repairing. Is it real? Check the ignition electrode gap. These boards are very sensitive to it. Perhaps this is the problem. Is it possible, before blindly buying a new DHW sensor, to check if it is not working? All sensors can be checked by resistance, and the DHW sensor is no exception. The value should be 1 kΩ at 25 degrees. I have a gas boiler Neva Lux 8023 installed, moreover, since I am going to use it with liquefied gas, it was reprogrammed. I also changed the nozzles to 0.79, adjusted the minimum and maximum gas pressure. But I did not do something, because there are no problems with heating, but the water for household needs does not rise above 27C. The water pressure itself is average, but even if it is further reduced, it does not help much at 50C, the maximum to which it was possible to heat the water. I measured the water flow at the inlet, it was 20-30 liters per minute. Where to look for the reason? Look at your passport. And bet the maximum you can. When hot water is in operation, Neva Lux 8224 (installed in 2009) does not maintain water at the same temperature. It gets hotter and colder. The device does not show any errors, it works as if it was in good working order. From the nuances: six months ago, when the water was turned on for household needs, he began to howl and make extraneous sounds. And when the heating is working in the boiler room, there is silence. The water pressure is good. What could have broken? Pay attention to the cyclical operation, that is: turning on and off when heating. And see if the uninterrupted water supply is being observed (you need to look at the flashing pictogram). Most likely, it is time to carry out maintenance. You have problems with the heat exchanger, a lot of water has already passed through it, and it has grown corny from the inside. Correspondingly poor heat dissipation. And the cyclical nature of the work is precisely because of this: it is already heated to the maximum, but there is still no water on the hot water supply. Since there is a problem with heat dissipation, it turns off and waits until it cools down. Then it works again. But heating is still a problem, that's the temperature drops. Neva Lux 8230, all summer was off. In the fall of this year, it was necessary to partially heat the house - it became chilly. After turning on, it normally ignited, and then a problem appeared.The device very quickly raised the water temperature to the required one and turned off. Thought the pump had jammed. Dismantled it, turned the shaft with a screwdriver - free movement. Asked different speeds of work - everything is correct. And still, quick heat up and stop. And also the outlet nut on the pump gets very hot. It feels like something is stuck in the pump and the water does not pass any further. Is it possible? Check the three-way valve actuator. It happens that contact leaves and problems begin. Neva Lux 8224 (Baltgaz), discovered the following problem: the post-circulation pump does not turn off, no matter what the temperature is. To make sure that this is so, he raised the temperature in the heating system to 60C. He turned off the flame. Then I set the temperature in his settings to 30C, so that it would stand in the pause mode for a longer time, and began to observe. The pump did not turn off for a second. And as I understand it, it is impossible to control it from the outside? In theory, if the basic settings are set, then the post-circulation pump should work for 3 minutes. There is a parameter P3, it is he who sets the minimum time from stopping the pump to turning it back on. The adjustment range of this parameter is from 0 to 14. Try to play with this value, for example, put 5. If the situation does not change, then this is a software failure. After an emergency shutdown of the gas, error 01 is constantly displayed. Restarting did not solve anything. There is no water heating. How to fix? Try restarting first. It does not depend on the phase, so if the boiler does not see the flame, then it really does not exist. It is also possible that you have an air lock in the pipe, or something is interfering with the flow of gas. Check it out. I have an outdated and discontinued Neva 7023 boiler at home. When I plugged it in, I heard a loud sound. After that, he refuses to work. The called specialist said that the board burned out and replaced it. Still, the work was not perfect. Once every couple of days, it turned off. We installed a room thermostat - the master advised us to do this. And after that, the E7 error began to pop up constantly. Again I had to turn to specialists. They thought for a long time and turned off all the buttons on it so that the adjustment was only from the thermostat. He worked for a couple of days and got up again. And it did not work to start it with the "reset" button, as it was possible before. Should I summon the master again? And so every time? In winter? In your boiler, an E7 error means that the coolant temperature has exceeded the permissible value. There may be several reasons for this: Broken temperature sensor. Incorrect settings were made after installing the new board. The fee itself came across to you with a marriage (this rarely happens). You forgot to carry out maintenance for more than two years and your heat exchanger is clogged. Or rather, the circulation of the coolant is disrupted. Neva Lux 8624 does not want to work in winter. If the outside temperature is below -25, then error 03 immediately appears and he gets up. There are two ways to start it: Reboot. Blow out condensation from silicone tubes. Installed it in 2010 and all these years there was such a problem. Everything else is fine and works fine. What can be done to fix the defect? The problem can be solved in several ways: Put a silicone tube from Vaylant (it still has a hole in the transition between two pipe cuts). Take a silicone tube and insert a medical needle into it, so that the diameter of the hole is about 1 mm. And direct the needle towards the pitot tube. Make a hole in the pressure switch with a diameter of 1 mm. Perhaps the error itself is not due to condensation. Frosting on the end of the tube can interfere with the air flow and cause problems. I installed a new boiler (produced by Baltgaz), but myself, since it took a long time to wait for specialists, and it was rapidly getting colder outside. So I obviously don't have a guarantee, I'll have to figure it out myself. It was launched strictly according to the instructions. Filled with water, blew air from the pump.I did not count on the heating system itself, but I checked all the nodes for air jams. There are no problems, except for a warm floor in one room, but there is a problem with installation (a branch from 32 pipes to 16, without a comb and an additional pump), apparently it cannot push water through such a constriction. Another pressure gauge is installed on the system, and its readings coincide with the readings of the unit. There is an Italian pressure gauge on the return line, and it shows 1.8 (when the readings on the boiler are 1.5). Want to understand what the problem is? Maybe I can fix something myself? Yes, and if I call the master, I would like to protect myself from unnecessary and meaningless spending, at least roughly representing the direction of the repair. I have filters installed on the water: the main one on the incoming water (thread, 5 microns), and on the hot water supply (polyphosphate). Everything is as recommended by the manufacturer. If you turn off the DHW circuit, then there are no problems in operation. And it is also connected in a level way: Resant stabilizer 3 kW; UPS 3.5 kW with online conversion. Since we have sudden power outages, I decided to protect myself in this way. In your case, it is recommended to contact a service organization. My Neva Suite 8029 is broken. It completely ignites and the E2 error lights up on the display. When water is supplied, there is no spark (ignition transformer does not work). And after all this, the fan on the hood works and is not going to turn off. And it works even if you turn off the front panel with a button. I checked the transformer circuit, since the relay clicks when triggered. But I do not know what the voltage should be in order to check it with a tester. Tell me? A voltage of 220V is supplied from the board to the ignition unit. To check, you can connect a normal live wire, the board should start clicking to supply a spark. If there is no reaction, then the ignition unit is definitely broken. Buy a new one, they are not repaired. I have a NevaLux 7023 double-circuit boiler installed. Recently, it began to lose pressure when working with hot water supply. At the same time, the number 95 is lit on the indicator and an error E7 appears. This does not heat up the water. If you reduce the water pressure, then the pressure stabilizes, and the error disappears. The numbers on it become 48, and the water temperature is already high enough. But not for long. Then the problem repeats again. With all this, heating works perfectly. What could have caused this problem? And how to solve it? A malfunction has occurred. In the summer, we did not need hot water, not heating, but the time came when we needed to turn on the boiler, but at startup, a problem with circulation was discovered. I called specialists who diagnosed a pump breakdown and for about a week have been trying to find a replacement for it. I am also lucky that the unit has a slope and can work without a pump. True, it now works in a cycle: it works for 2 minutes, it costs 2 minutes. I have a Neva Lux 8029 and a Wilo NFSL 12/4 pump. Is there any way to fix them? The pump heats up slightly more than the incoming water. Try to turn the shaft inside the pump by first unscrewing the screw. If the shaft is jammed, then this is definitely a purchase of a new one. In order to avoid such a problem in the future, you should not turn off the pump, it is enough to switch it to summer mode. Then the boiler itself will periodically circulate and the pump will not sour. A long time ago my Baltgaz boiler broke down. All hands did not reach to fix it, since I still have an electric boiler. But all the same I decided to do it. I decided to check the secondary heat exchanger. And it cannot be removed, because of the engine of the three-way valve (there is no access to one of the hexagons). As a result, I disassembled everything and removed the heat exchanger. Then I washed it very thoroughly with water. A large number of various small stones (flat and dark gray) were washed out of it. But, despite their presence, the flow through the heat exchanger was still preserved, although it was difficult. Tried to buy a special flushing solution, but all the shops were already closed.Then I decided to use cola. He warmed it up and poured it into a heat exchanger. Then I used citric acid - soaked in it for an hour. I washed everything again, although I did not see any special changes. It should be noted that the stones were only on the heating side. I began to check the sensors and the three-way valve further. The sensors reacted as it should, from which I concluded that they are completely serviceable. Next came the turn of the three-way valve. Having disassembled it, I did not find anything wrong. The spring is tight, the rings are intact, the valve itself is without burrs. Confused only by the fact that the resistance of the engine instead of 15K, was only 9K (maybe different models?). When I put everything back, it worked. I also cleaned the sump on the return, it was heavily soiled.

___________________________________________________________________________________________

___________________________________________________________________________________________

Repair of gas boilers AOGV Borino, ZhMZ, Siberia, Alpha Calor, Thermotechnik. Adjustment of gas automatics Eurosit 630. Replacement of the thermocouple and maintenance of the ignition burner.

Malfunctions and repairs of Baxi boilers Models Luna, Luna 3 Comfort, Luna Duo Tec (F / Fi). Double-circuit, turbocharged. Recommendations for eliminating errors and malfunctions. Settings and adjustment of operating modes.

Gas heating boilers Bosch Models ZWC, ZSA, ZSC, ZWR, Gaz 5000, Gaz 3000 W ZW, WBN 6000. Wall-mounted, double-circuit. Repairs, adjustments and malfunctions. Options for setting functions and modes.

Repair recommendation Navien Models Deluxe Coaxial, Deluxe Plus, GA. Errors and malfunctions. Work with remote control Ksital. System control. Setting work on temperature and pressure.

Floor standing boilers Buderus Repair of Logano G124, G125, G215, G234, G334 models. Breakdowns and malfunctions. Operation with Logomatic control system and indirect heating boiler. Modes and functions.

Operation of Vilant boilers Turbotec Atmotec pro / plus VU / VUW INT models. Components and work functions. Adjustment programs. Gas system. Installation and assembly. Maintenance and prevention.

Floor standing boilers Protherm Repair of the Bear models KLOM, KLZ, TLO, PLO with a capacity of 20 to 50 kW. Breakdowns and malfunctions. Operation, maintenance. Recommendations for setting operating parameters.

Lemax - repair and settings Models of gas floor boilers Premium, Leader, Patriot. Performance characteristics. Prime, Wise models. Adjustment of automatic equipment Eurosit, Minisit, Sit Nova. Solid fuel boilers Forward.

Wall-mounted coppers of Protherm Repair of the Panther, Cheetah, Jaguar, Lynx, Leopard models. Breakdowns and malfunctions. Operation and service. Recommendations for adjusting operating modes.

Beretta - repair and adjustment Repair and operation of boilers Ciao, City, Novella, Exclusive. Wall and floor models. Malfunctions and error codes. Working functions and setting of service modes. Maintenance.

Boilers Teplodar Kupper PRO Operation and adjustment of solid fuel boilers with a capacity of 22, 28, 36 kW. Installation of an automatic pellet burner APG-25, 36, 42. Settings of operating modes.

Repair of gas boilers Oasis Models of wall-mounted boilers ZRT, ZRN, BM. Malfunctions and error codes. Troubleshooting tips. Operating modes and setting of service parameters. Maintenance.

Heating boilers Alfatherm Description of Beta floor-standing boilers and Sigma wall-hung gas boilers. Malfunctions and error codes. Repair and troubleshooting questions. Basic maintenance work.

Wolf - malfunctions and repairs The Wolf boiler is installed. I noticed that over time, the pressure in it gradually decreases (by about 1 in 2 days). I checked all the pipes for leaks but found nothing. What else to check?

Gas boilers Junkers After 7 years of operation, the gas boiler Junkers ZW-23-KE has the following problems. When DHW starts working, it either turns off or stops working ...

Repair of boilers Neva Lux Neva Lux 8224 (Baltgaz), discovered the following problem: the post-circulation pump does not turn off, no matter what the temperature is. To make sure that this is so, he raised the temperature in ...

Neva Turbo boiler

On the quality and ease of use, users left various reviews: positive and negative. Over time, all the necessary adjustments resulted in the production of a separate series of heating devices.Neva Turbo units are, by and large, a modified version of the already familiar Lux series.

All the shortcomings were taken into account here. The technical characteristics of the models are as follows:

  • closed combustion chamber - here there is a forced supply of air by means of a fan. Smoke removal is carried out using a special device through - a coaxial chimney;
  • automation - wall-mounted gas double-circuit boiler - Neva Turbo is fully adapted for operation. A multi-level system of sensors and valves is responsible for the safety of the equipment and the regulation of heating. The package includes an autodiagnostics system, which automatically checks, the results of which are displayed on the liquid crystal display;
  • control - on the usual buttons. Using a conventional regulator, you can set the desired temperature regime, provided that the programmer is installed, select the conditions for operation for several days or a week. The optional kit includes a room thermostat. The sensor generates a signal to turn off the heating when the room heats up to the desired temperature.

Turbo boilers are volatile units. The electric power supply of the boiler is achieved by connecting it to a conventional 220 V mains.

New product of the company - boiler Turbo

As the Lux models were used, both negative and positive consumer reviews accumulated. Over time, all the necessary adjustments resulted in the production of a separate series of heating equipment.
Neva Turbo boilers are, in fact, a modified version of the already familiar Lux modification, taking into account the shortcomings of previous versions. The models have the following specifications:

Turbo boilers are volatile. The power supply of the boiler is provided by connecting to a regular voltage network of 220 V. For stable operation, you will need to install a UPS and a generator.

Easy to maintain and operate

Regardless of the model chosen, the installation of a wall-mounted boiler takes place quickly and without the need for additional costs. The manufacturer focuses on the convenience of installation and subsequent operation. Therefore, the boilers of the company, in fact, represent a station already ready for operation.
It is enough to connect the unit to the heating and power supply system and start heating the house or apartment. In practice, provided that the heating system is already completed, all work takes about 3-4 hours.

Once installed, there is no need to worry about the safety of the station. The sequence of the automation completely excludes the possibility of gas leakage, creating an emergency, even if an unplanned power outage occurs.

The main differences between Neva boilers

A simple device and operation make it possible to distinguish Neva boilers among all domestic heating equipment. Today, in terms of their characteristics, boilers are in no way inferior to foreign equipment and have a more attractive cost.
The Turbo modification provides economical gas consumption and, if properly operated, pays for itself in a few years.

Calculation of the power and temperature of a warm water floor

Russian wall-mounted gas double-circuit boilers Neva provide consumers with maximum comfort when switching to autonomous heating and hot water supply. This equipment is intended for use in apartment buildings and country houses. For the production of boilers, modern materials are used, as well as high-quality components from the best European suppliers. The designers of the enterprise are constantly researching, testing prototypes of new models on an experimental one before launching into mass production.Thanks to this, it is possible to correct all the shortcomings, the manufacturability of production increases and, which is important for gas equipment, the degree of its reliability increases. Domestic manufacturer BaltGaz has implemented two design options for gas by-pass boilers Neva Lux. So in the 72 series boilers, as well as in the BaltGaz 18 DBF boiler, a single bithermal heat exchanger is installed to work with heating and hot water circuits. This decision made it possible to reduce production costs, which had a positive effect on the pricing of these products. In addition, the 72nd series products provide accurate temperature control with a tolerance of 1 0 C. The 82nd and 86th series models use a traditional layout with two heat exchangers - copper for the heating circuit and plate for the hot water supply circuit. The entire line of double-circuit boilers, with the exception of the Nevalux-8624 model, is equipped with a closed combustion chamber. In addition to the above, Nevalux gas by-pass boilers differ in thermal performance and minor design details:

  • Nevalux-7211 - thermal power 11 kW, bithermal heat exchanger, maximum heating area - 110 m 2
  • Nevalux-7218 - thermal power 18 kW, bithermal heat exchanger, maximum heating area - 180 m 2
  • Nevalux-7224 - thermal power 24 kW, bithermal heat exchanger, maximum heating area - 240 m 2
  • BaltGaz 18 DBF - thermal power 18 kW, bithermal heat exchanger, maximum heating area - 180 m 2
  • Nevalux-8624 - thermal power 24 kW, copper heat exchanger (heating) and plate heat exchanger (DHW), maximum heating area - 240 m 2
  • Nevalux-8224 - thermal power 24 kW, copper heat exchanger (heating) and plate heat exchanger (DHW), maximum heating area - 240 m 2
  • Nevalux-8230 - thermal power 30 kW, copper heat exchanger (heating) and plate heat exchanger (DHW), maximum heating area - 300 m 2

The rest of the components of this heating equipment are similar to Nevalux single-circuit wall-mounted boilers. This is a modulated burner with continuous flame control, and built-in safety elements, and electronic control. All Nevalux wall-mounted double-circuit gas boilers are pre-configured to operate on both natural and liquefied gas, and the design features ensure stable operation of the equipment even with low gas pressure in the supply line.
Wall mounted gas boilers are in great demand among consumers who have a house or a small cottage. This is due to the advantages of this type of equipment. Thus, the wall-mounted boiler is distinguished by its small external dimensions, due to which the equipment can be installed indoors with minimal loss of space. The equipment does not make noise during operation and is capable of stably performing the assigned tasks, regardless of operating conditions. Many users choose the Neva Lux two-circuit gas wall-mounted boiler for installation in the heating systems of their homes, with the advantages and main technical characteristics of which we will get acquainted below.

Most popular models

Consider the models of gas boilers of the BaltGaz company, which are in stable demand.

Neva Lux 7218

The Neva Lux 7218 boiler is the best option to supply heat to rooms with an area of ​​up to 180 m². The hot water supply circuit is necessary to increase comfort and provides residents with hot water. The package of this double-circuit boiler includes a bithermal heat exchanger, thanks to which all user functions remain at a high level.

Distinctive features of the device design and technical characteristics are as follows:

  • closed combustion chamber;
  • the operating temperature in the heating circuit and hot water supply is between 30 ° C;
  • thanks to additional settings, it is possible to switch the equipment operation to liquefied gas;
  • the performance of the Neva Lux 7218 boiler is very high, the efficiency reaches 90%;
  • thanks to the electronic unit, the flame is continuously monitored. This is carried out both during the operation of the heating circuit and the hot water supply circuit;
  • all components are European, due to which the unit has a large number of positive user reviews.

Neva Lux 8224

This unit is wall-mounted. Consider the design features of the device:

  • high power makes it possible to use 8224 double-circuit units for supplying heat to premises with an area of ​​up to 250 m²;
  • the unique combustion chamber is water-cooled, which increases the service life of all structural elements by several times;
  • microprocessor software, which is present in the boilers of this model, determines the maintenance of the set temperature regime. The error is less than 1 °;
  • in addition, the package of this device includes two heat exchangers: copper is intended for heating; plate, made of stainless steel - for hot water supply.

Instrument control in the 8224 has been improved with a remote control option and PC connection for diagnostics and the ability to fine-tune hardware.

The heaters of this model have a digital display on which all information from an automatic self-diagnosis system is displayed.

Neva Lux 8618

The wall mounted gas boiler Neva Lux 8618 is a single-circuit gas boiler. Compared to floor-standing units of the same power, this model has a higher performance, the efficiency is 90%. The boiler is also characterized by a reduced gas consumption.

Neva Lux 8618 wall-mounted units are distinguished by the following characteristics:

  • due to its compact size, such equipment can be installed even in small-sized rooms, they will not take up extra space;
  • a large number of positive reviews testify to the reliability of the equipment. The devices are suitable for Russian conditions;
  • thanks to the built-in circulation pump, the boilers can be installed in ready-made heating systems.

In addition, you can connect an indirect heating boiler, a forced smoke exhaust fan, a room thermostat to such boilers, thanks to which the equipment is highly economical.

These gas boilers can operate at a reduced pressure of 0.3 bar.

The main types of boilers Neva Lux


Models and technical characteristics of boilers

The lineup includes 2 basic modifications - Turbo and Lux. Turbo boilers are volatile. For their uninterrupted operation, uninterruptible power supplies, a 220 V network, and an electric generator are required.

The Neva Lux boiler is thermostatically controlled. Automation works completely autonomously and reduces fuel consumption. As a result of automatic regulation, the control unit independently adjusts the temperature regime depending on the degree of heating of the room.

Double-circuit gas boiler

Traditionally, the company produces models for main gas. But for those who have only liquefied in stock, several models are produced.

Double-circuit gas boilers are designed for heating and hot water supply. Owners of apartment buildings can refuse utilities and provide themselves with hot water themselves. It will come out cheaper. The water temperature can be adjusted.

Single-circuit gas boiler

Models with one thermal circuit are smaller than dual circuit models in size. Their operation is much easier. They only maintain the temperature of the coolant in the heating system.Of the current off-season maintenance, the most important thing is cleaning the working chamber and chimney from carbon deposits. Annual maintenance will prevent significant operational problems.

Maintenance and operation

Regardless of which model you prefer, the installation of a wall-mounted boiler is carried out as soon as possible without any additional costs.

The manufacturer focuses on the convenience of installation and subsequent operation of the unit. That is why the heating devices of the Neva Lux company are a completely ready-to-operate station. You just need to connect the equipment to the heating system and power supply and start heating the room. As practice shows, all work takes 3-4 hours. Once the installation has been completed, there is no need to worry about the safe operation of the station. Consistent operation of the automatics minimizes the risk of gas leakage, emergencies, even in the event of an unplanned power outage.

Installation features

It is worth mentioning that a wall-mounted double-circuit gas boiler is a self-sufficient system and it is not difficult to install and connect it. In order to carry out the installation and piping of the gas boiler, you must use the following components:

  • ball valves, they will be responsible for cutting off water;
  • mains and heating circuit;
  • all kinds of drives;
  • coaxial chimney, which is included in the boiler package.

In order to protect the heater from all kinds of impurities, it is necessary to install some filtering parts: gas, magnetic and coarse filter.

The sequence of installation of a wall-mounted BaltGaz gas boiler is as follows:

  1. The Neva Lux unit is mounted by means of special strips that are included in its package. In order to securely fix these planks to the wall, it is best to use anchors.
  2. Ball valves are placed at the inlet and outlet of the boiler of the hot water supply and heating circuit. Subsequent maintenance of the unit will be much easier.
  3. Next, you need to install all the required filters using suitable squeegees.
  4. Then you can start installing the heating and DHW circuit or connect to existing piping systems.

All connections and installation of the filter must be carried out by specialists who have permission to do this.

It is better to choose a kitchen or other room in the house where there is a ventilation hole as the location of the unit. This is prescribed by the rules for the operation of gas equipment and general safety. In addition, when choosing an installation site, you need to take into account the convenience of supplying communications: water and gas pipes, electrical wiring.

User reviews confirm that Neva Lux gas boilers are efficient heating devices. If you make the correct installation, then you do not have to worry about the safety of the equipment. Thanks to modern automation, the risk of emergencies is reduced to zero.

Source: teplofan.ru

Error H1 - insufficient heating

The column does not heat the water to the specified temperature.

Reason # 1. High temperature set at high head. The column cannot cope with heating the amount of water that passes through the column. Reduce head.

Reason # 2... Burner clogged with dust. If you notice that the gas is burning orange, and the flame is sluggish and elongated, then it's time to clean the burner. If you neglect cleaning, then this error will appear constantly. The efficiency of the column will be halved. A lot of soot will appear.

  • Annual cleaning →
  • The column does not light up →
  • Poor or not heating water →
  • Suddenly disconnects →
  • The wick goes out →
  • The gas water heater goes out →
  • Column rinsing and cleaning →
  • Burner cleaning →
  • Soldering the radiator →
  • Replacing the membrane →
  • Installation and assembly →
  • Scheme and device →
  • Column breakdowns →
  • We fix water heaters →
  • Buy a new column →

About the popular Neva Lux 8224

If you need a reliable double-circuit boiler, then it makes sense first of all to take a closer look at this particular model, because it can rightfully be considered one of the exclusive offers on the market for such modest money. What is the peculiarity of this technique?

BaltGaz products

It is no secret that domestic products at all times have been much cheaper than their European counterparts. And it is precisely the democratic price that is the main advantage of the Neva Lux 8224 model in comparison with imported competitors. In fact, a Russian can, for relatively little money, acquire a modern reliable unit with built-in automation, low fuel consumption and high performance.

It is obvious that the BaltGaz company, striving to satisfy the maximum wishes of the buyer for relatively little money, "presented" the Neva Lux 8224 units with a complete set that is quite extensive for its price segment. Note the following features of this design:

  • The presence of two heat exchangers - for hot water supply and heating;
  • The ability of the unit to independently maintain the temperature of the coolant at a given level with an error of 1 degree Celsius;
  • Possibility of aggregation with an external thermostat;
  • The presence of a multi-level security system that guarantees a long service life;
  • Electronic control of the burner, automatic ignition system, as well as constant electronic flame modulation;
  • The presence of a liquid crystal monitor, which allows you to contact the equipment through a convenient and intuitive interface;
  • Availability of a system for self-diagnosis of errors and malfunctions;
  • Built-in circulation pump and large expansion tank for safer system operation.

It is no secret that for an average European-made boiler, a set of options for the Neva Lux 8224 gas boiler is considered the norm. Most modern German boilers are equipped with much more advanced security systems, and in terms of efficiency they are superior to domestic technology. And, nevertheless, the democratic price and reputation of the company both became the reason for considerable demand for the Neva Lux 8224 gas boiler.

Let's take a closer look at the technical parameters of this model in order to make sure that its popularity in the domestic market and the market of the CIS countries is really deserved.

Technical features of the model

The Neva Lux 8224 unit is equipped with a closed combustion chamber, in which air is pumped using a built-in turbine. A pipe is supplied with the equipment to facilitate the installation of equipment.

This model has two heat exchangers for DHW and heating. The rated power of Neva Lux 8224 reaches 24 kW, which means that owners of living space up to 230-250 square meters can safely buy this device, as it will provide the house with heat at any time of the year.

In its most efficient mode, the boiler consumes 2.62 cubic meters of gas. At the same time, the unit boasts a fairly high efficiency at the level of 92.5%. At a coolant temperature of 25 degrees Celsius, the Neva Lux 8224 gas boiler is capable of producing up to fourteen liters of hot water per minute.

The kit with the Neva Lux 8224 boiler comes with an instruction that will facilitate the installation process. At the same time, before installation, it must be borne in mind that the boiler has a heating circuit inlet and outlet G 3/4 ", a gas inlet G 3/4", as well as an inlet and outlet for the DHW circuit G 1/2 ".

The light weight with packaging of 36.5 kg and the modest dimensions of 720x410x326 mm greatly facilitate the installation of the unit and its transportation from the place of purchase to the home.At the same time, do not be confused by the low weight - the device is designed for operation in the extreme conditions of Siberia at low temperatures and works more seriously than it looks.

findings

Russian engineers very seriously approached the creation of a universal heating unit, which is evident from the design of the Neva Lux 8224. If you, as a buyer, are looking for harmony between price and quality, then many market experts will advise you on this particular model, because reliability, ease of use and adaptability to Russian conditions are the fundamental advantages of this boiler.

Source: prostokotel.ru

Error E1 - no flame

Ignition clicks for about a minute the burner does not ignite. The electronic control unit does not see the presence of a flame and the column goes into emergency mode.

Reason # 1. The presence of air in communications. Prolonged downtime of the column, or after its installation, the operation of the ignition burner will occur only after air has been removed. The system should be purged by constantly turning on the column. Since the ignition lasts no more than a minute, after completion you should reopen the water tap until the ignition occurs.

Reason # 2. Lack of gas in the cylinders or the valve on the lowering to the dispenser is closed. Open the shut-off valve fully. Check LPG cylinders. Replace them if necessary.

Reason number 3. There is no contact between the unit and the flame detector. It is necessary to service the contacts coming out of the electronic unit, if necessary, clean them, press them for a good connection, replace the worn ones.

Reason number 4. Flame presence detector outside the flame zone. Adjust the position of the flame detector so that its electrode is in the gas combustion zone. Make sure that the electrode does not touch other metal components. Clean the electrode from carbon deposits.

Reason number 5. The gap between the ignition plug and the igniter is broken. From constant heating and cooling, the pilot burner nozzle is deformed, which increases the gap to the spark plug. Once every two years, or with a regulated maintenance, the gap should be adjusted to 4… 5 mm.

nevalux errors

Rating
( 2 grades, average 4.5 of 5 )