Instructions for the operation and repair of gas water heaters with their own hands Vector JSD20 W


Dear customer ...

Page 2

  • Picture
  • Text

2

Dear customer!

You have purchased a gas instantaneous water heater with an electronic device

vom, allowing it to automatically ignite when you open the hot water tap.

The device has a digital indicator that allows you to control the temperature

a round of heating the water flowing out of the tap (only for model JSD20-W).

Thank you for choosing our water heater. When purchasing the device, check the completeness, and also require filling

sales organization of coupons for warranty repairs.

This instruction manual contains information on how to install

device, rules of use and maintenance, on safety measures during the operation of the device, the observance of which will ensure long-term trouble-free and safe operation of the product. Please read it carefully and follow the directions in it.

VEKTOR water heaters have all the necessary certificates and are allowed

to installation.

Installation of the device, instructing the owner on the principles of operation and rules

the operation of the apparatus, maintenance is carried out by the operational organization of the gas economy or other organizations, licensed

for this type of activity.

Checking and cleaning the chimney, repairing and monitoring the water supply system-

communications are carried out by the owner of the device or house management.

Responsibility for the safe operation of the machine and for keeping it in

the proper condition is borne by its owner.

If you have any questions about quality, you could not explain all the advantages

property of VEKTOR water heaters or did not explain the principle of operation, please contact the following phone numbers:

in St. Petersburg (multichannel)

in Moscow, 741-77-67

in Krasnodar, 68-09-52

Please be advised that the water heaters listed in this manual are designed

nerds for home use only.

Thank you for purchasing

our water heater!

Features of the geyser Vector

Gas column Vector

The most popular models of gas water heaters are Chinese product - "gas column Vector". Customers from Russia control the orders of this product.

Testing and quality control of gas water heaters is carried out at the factory. All this is done by qualified specialists.

Gas water heater "Vector" is a popular model among consumers in the Russian market. But the reviews about the gas column "Vector" are contradictory.

1 Unit advantages

style = "display: block" data-ad-client = "ca-pub-9337857885889635 ″ data-ad-slot =" 9967522739 ″ data-ad-format = "auto">

The Chinese product is very well thought out in the security system. The craftsmen took into account all the details of the work of the gas column. The safety system prevents the column from burning without water supply, an automatic shutdown is triggered here when the column overheats, or if water boils.

It was also provided for automatic shutdown of the device in the absence of chimney draft. The geyser "Vector jsd20 w" was equipped with a built-in automatic electric ignition. There are also many more positive aspects when using this product.

If you look at the Lux Eco vector gas water heater model, then such models are equipped with a clock on the displays that give information about the temperature of the water in the tank. This is a very handy feature. And the installation of a gas water heater also does not require exorbitant knowledge.

"Vector Lux" has a good power, which can easily provide several points of water intake, such as in the kitchen and bathroom. And this is all important. It should be noted that this product plain in management.

Gas water heater Vector in a private house

A skilled craftsman is always will explain and will find the reason for the breakdown of this product. The prices for spare parts and cleaning of Vector gas water heaters are below average, which allows for repairs, and this will not cost much.

2 Disadvantages of Vektor gas water heaters

When using the device, the most frequent malfunctions of the Vector gas column are weak batteries, which provide automatic ignition - they should be changed frequently.

In this case, you need to use expensive high-quality batteries. Also, the disadvantage is that the protection system is configured too tightly in the device. Stable water pressure and good water flow are required for normal operation.

There are drawbacks in changing the outlet water temperature, and this happens if there are large pressure drops. In these cases, automatic temperature setting is used, and the Vector gas column does not have it.

It looks like a gas water heater Vektor

It will be difficult to manually set these settings. The most common breakdowns are as follows:

  • gas column Vector does not light up;
  • no spark on the gas column Vector.

These are the most common breakdowns. Also, breakdowns are less common, like a cracked heat exchanger tube. The device of the Vector gas column is not convenient, since when removing the heat exchange unit to clean the unit, you will encounter many difficulties.

Attention! If your Vector gas water heater does not light up, then you need to immediately call the wizard, since fixing a breakdown in such models with your own hands is a great danger (explosion, fire).

It should be noted that not every store has a complete list of spare parts for the unit. There are also cases that even "GORGAZ" refused to repair given the unit, since employees are not familiar with the device of the column.

They demanded a Vector gas water heater scheme, but the consumer often did not find it. A significant drawback of this unit is that, with prolonged use, the process of turning it on often breaks down. Explosion may occur due to untimely ignition of the gas. At the same time, consumers experience fear when they turn on the column. If you don't turns on gas water heater Vector, it is better to call a qualified technician.

If you listen to numerous reviews, you can come to the conclusion that the Vector gas water heater is not operated as easily as it seems at first glance. Such a device requires understanding several basic principles of this unit. Even experienced specialists have the question of how to disassemble the Vector gas column?

2.1 Design and principle of operation of the column Vector

The design of the unit is very simple. In principle, she is no different from her fellows. Consists of:

  • Burner main;
  • Ignition;
  • Heat exchanger.

The Vector Lux gas water heater consists of a painted metal frame, which is very similar to an ordinary kitchen cabinet. The above elements are located inside this frame. Two pipes emerge from the bottom of the frame. One for gas supply, the other for water.

Gas column device Vektor

The principle of operation of the unit is also simple. All models have automatic ignition type. This means that the column turns on after you turn the jib crane.

After you have opened the rotary valve, a valve is triggered in the column system, which slowly passes gas into the pilot burner, and then into the main burner. After that, the gas burns out and the column releases heat and energy to quickly heat up cold water. Cold water passes through a spiral tap (heat exchanger) and hot water is supplied to the tap. It should be noted that the Vector gas water heater can work without a chimney, and this affects the low cost of installation.

Source: https://seositi.ru/otoplenie/kotly/gazovaya-kolonka-vektor.html

SAFETY PRECAUTIONS …………………………… ..

Page 3

  • Picture
  • Text

3

CONTENT

SAFETY PRECAUTIONS …………………………………………………………………… 4

DESCRIPTION AND OPERATION OF THE PRODUCT …………………………………………………………………… .. 5

2.1 Purpose of the product ………………………………………………………………………………… .. 5 2.2 Technical characteristics ……………………… …………………………………………………. 5 2.3 Product composition …………………………………………………………………………………………. 5 2.4 Description of the apparatus and the purpose of the main units …………………………………………. 8 2.5 Overall and mounting dimensions …………………………………………………………… .. 9 2.6 Electrical circuit …………………………………… …………………………………………….. 12

INSTALLATION PROCEDURE ……………………………………………………………………………… .. 13

3.1 Installation site ………………………………………………………………………………………. 13 3.2 Installation of the device …………………………………………………………………………………… .. 13 3.3 Water connection ………………… ………………………………………………………………… .. 14 3.4 Gas connection ………………………………………………… ……………………………………. 17

3.5 Connecting the device to a bottle with liquefied gas ……………………………… .. 17

3.6 Installation of a flue gas flue (except for model JSD11-N) 17 3.7 Installation of a JSD11-N water heater (without connection to a flue) ………………………………………………………………………………………………………………………………………………………………………

USING THE MACHINE ………………………………………………………………………. twenty

4.1 Switching on the device ………………………………………………………………………………… 20 4.2 Regulation of the degree of water heating ……………………… …………………………………. 20 4.3 Switching off the device for a long time ……………………………………………… .. 21 4.4 Protection against freezing ………………………………………………… ……………………. 21

MAINTENANCE ……………………………………………………………… .. 22

5.1 Inspection ……………………………………………………………………………………………………. 22 5.2 Care ……………………………………………………………………………………………………… .. 22 5.3 Maintenance… ………………………………………………………………………. 23

5.3.1

Cleaning the burner

…………………………………………………………………………………………………………. 23

5.3.2

Cleaning water and gas filters

………………………………………………………………………………. 23

5.3.3

Cleaning the heat exchanger

…………………………………………………………………………………………. 23

5.3.4

Replacing sealing joints

…………………………………………………………………. 24

5.3.5

Checking the tightness of the gas and water systems of the apparatus

……………………… 24

5.3.6

Checking the performance of the thrust sensor

………………………………………………………. 24

5.3.7

Checking the performance of the heat exchanger overheating sensor

…………….. 24

5.3.8

Extraordinary cleaning of the machine

……………………………………………………………………………. 24

5.3.9

ODS sensor performance check (for model JSD11-N)

POSSIBLE MALFUNCTIONS OF THE APPARATUS AND METHODS OF THEIR ELIMINATION…. 25

STORAGE RULES …………………………………………………………………………………. 27

WARRANTY ………………………………………………………………. 28

ACCEPTANCE CERTIFICATE ……………………………………………………………………… 28

10 NOTICE ABOUT INSTALLING THE APPLIANCE AND PERFORMING MAINTENANCE ……………………………………………………………………………………………… 29

teplomex.ru

Geysers Vector appeared on the Russian market for a long time. These flow-through gas water heaters are assembled in Russia from Chinese components and spare parts.

Due to its low price and compact size, the Vektor JSD 20-W geyser quickly occupied its niche: an inexpensive and modern gas water heater, as evidenced by numerous reviews on the Vector columns.

Today we will also consider the model range and their device, advantages and disadvantages, as well as technical characteristics and spare parts of Chinese speakers of the Vector brand, and draw up a subjective instruction for use.

Model range of speakers brand Vektor and their price

Geysers of the Vector brand are supplied in two basic configurations:

Vektor JSD 20-W; — Vektor Lux Eco 20-3 (-2).

Geysers Vektor Lux Eco

Geysers of the Vektor JSD 20-W model were very popular at the beginning of this century. In fact, at that time these were the cheapest gas water heaters, they could be bought for 3,500-4,000 rubles. In addition to their low price, they had compact dimensions, a digital display on the front of the device, automatic ignition from batteries, and were produced in three colors: white, silver and gold.

In recent years, the company has launched the production of Vector gas water heaters of the Lux Eco series at a price of 7000-8000 rubles. Like the Vektor JSD 20-W models, these dispensers are equipped with a copper heat exchanger, automatic electric ignition, overheating protection that prevents possible water heater malfunctions, and a winter-summer system.

This system allows you to set the desired temperature mode using a special regulator on the control panel, depending on the water temperature at the inlet to the device, which is different at different times of the year: for example, in winter + 4, and in summer + 10.

Gas water heaters Vector Lux are produced with a glass front panel, like Zanussi gas water heaters, which have a different pattern. Thanks to this, the buyer can choose an appliance that matches the style and color of his bathroom or kitchen.

In addition, the columns of the Vektor Lux Eco series are equipped with the newest Eco smoke exhaust system, and the open combustion chamber has a special water cooling.

Gas column device Vector

The internal structure of the gas column Vector
1 - dispenser body 2 - frame 3 - water-gas unit 4 - water pressure regulator 5 - water temperature regulator 6 - solenoid valve 7 - gas burner 8 - heat exchanger 9 - overheating protection sensor 10 - draft sensor 11 - GOU 12 - ignition electrode 13 - flame control sensor 14 - battery box 15 - control unit 16 - display 17 - sight glass 18 - microswitch 19 - cold water inlet 20 - gas inlet 21 - hot water outlet 22 - safety valve 23 - outlet water temperature sensor
Basic elements and spare parts of a gas water heater Vector

1. The heat exchanger is the main element of the water system of the gas column. It has a tubular structure, inside of which cold water is supplied. Thanks to the hot vapors released by the gas burner, the water in the tubes of the heat exchanger is heated to the set temperature.

2. The water-gas unit of the gas water heater turns on the device when the tap is opened, and it is also responsible for the water temperature and gas supply to the burner. The water regulator only opens the gas valve to supply gas to the gas burner when there is sufficient water pressure. The gas regulator is released and controls the gas supply to the burner.

3. The gas burner burns the air-gas mixture for its subsequent supply to the combustion chamber of the column.

4. A gas outlet device (GOU) is used to divert products from the combustion chamber into the chimney, where a draft sensor is installed, which turns off the column in the absence of normal draft.

5. The overheating sensor automatically turns off the column when the water temperature reaches 80 degrees, the flame control electrode automatically turns off the gas supply when the burner flame disappears, and the ignition electrode gives the necessary spark to ignite the burner.

6. The safety valve serves to relieve excess water pressure, as well as to drain the water from the column.

Specifications

Speakers Vector: Specifications
Geysers Vector can operate on natural and liquefied gas. The device is ignited at a minimum water pressure in the system of 0.2 atmospheres. The hot water productivity is 10 l / min, which is quite enough for one tap: kitchen or bathroom.The diameter of the chimney pipe for this model is 110 mm, the water and gas connections are 1/2 '.
Advantages of geysers Vector

- low price - modern design - compact dimensions - cheap spare parts

Disadvantages of geysers brand Vector

- quality of components - thin walls of the heat exchanger - low productivity (one draw-off point) - no modulation of the burner flame (automatic maintenance of the water temperature)

Today, together with you, we examined the Vektor Lux Eco and Vektor JSD 20-W geysers. Disassembled the internal structure and its main elements, model range and technical characteristics of Chinese gas water heaters.

On geysers Vector, reviews write contradictory: someone is not satisfied with the quality, but someone, on the contrary, is pleased with the low price of the device. Do not forget that this water heater belongs to the segment of cheap gas water heaters, and you should not expect too much from it, but it fully justifies its money. Watching the video.

W dimensions overall and mounting ...

Page 10

  • Picture
  • Text

10

Fig. 2b. Vektor JSD12-W dimensions overall and mounting

W dimensions overall and mounting ...

Comments (1)

Highlight → I found instructions for my water heater here! #manualza

  • Click →

If you don’t want it in an amicable way, you will follow the instructions!

Manualza! Manualza.ru

Still not with us?

Dignity

The first and most important point, which is a well-thought-out safety system, which prevents the possibility of combustion without water supply, automatic shutdown when the heat exchanger overheats or water boils, in the absence of draft in the chimney.

Homeowners who have used the Vektor for a year or more will appreciate the convenience of the built-in automatic electric ignition.

The presence of a clock and a display giving information about the water temperature seemed important for consumers. The column has enough power to provide several points of water intake (for example, a bath-kitchen), it is light and easy to use.

A positive opinion about the Vector column was also formed due to its affordable price, the ability to purchase the unit in any store in several color options. Some users liked the presence of the winter-summer mode, but there are also remarks that it is impossible to understand why these very modes exist and how they differ.

In most reviews about the Vector gas water heater, it is noted that the stores always have the spare parts necessary for repairing the column, it is possible to use the service or the services of a qualified master, although there are remarks about the absence of both service centers and repair specialists.

Finding and eliminating the causes

So why doesn't the gas water heater turn on? A number of situations can be to blame:

  1. Error in connecting pipes;
  2. Lack of draft in the chimney
    ;
  3. High sensitivity of the protective relay
    ;
  4. Discharged ignition batteries
    ;
  5. Weak water pressure or its complete absence
    ;
  6. Dirty filters
    ;
  7. Membrane deformation
    .

Let us consider all of the above reasons in more detail and analyze effective methods of eliminating them:

Reason number 1: error in connecting pipes

The water heater protection system itself shuts off the gas supply if errors are made in connecting the pipes. To prevent this from happening, simply stick to a simple and understandable scheme:

Also, if gas does not flow into the gas column, check the position of all shut-off valves that can be installed on the gas pipeline. It is possible that after installing the device, you simply did not open one of the taps.

Reason number 2: lack of draft in the chimney

Due to the pollution of the chimney as a result of the accumulation of soot or the ingress of debris into it, the vector of movement of combustion products changes to the opposite. This poses two dangers:

  • Returning carbon monoxide / air mixture extinguishes the burner
    ... As a result, the protection system is triggered, and the operation of the gas water heater is blocked;
  • Returning carbon monoxide / air mixture seeps into living spaces
    ... This option is even worse, since it poses a danger to the health and even the life of household members. It is possible in the case when the force of the "overturned" thrust is not enough to extinguish the fire.

It is very easy to check the condition of the ventilation duct with your own hands. It is enough to bring a lighted match to the inlet: if the flame deviates inward, then the chimney is working efficiently, if not, appropriate measures must be taken.

Let's figure out what to do in the described situation:

PhotoDescription
Check first
Have someone installed a satellite dish over the outlet of the ventilation shaft. This may be enough to create a reverse thrust effect. In this case, the problem can be solved by negotiations with neighbors without calling a chimney cleaning specialist.
Call a professional to clean the ventilation duct.
If no external factors interfere with the release of combustion products, then the reason for the lack of traction is clearly the clogging of the chimney. You can try to clean it yourself, but there is a danger that you will damage the neighboring branches with your actions without appropriate experience.

Reason # 3: high sensitivity of the protective relay

Does the gas column light up, after which it soon fades? In this case, the problem most likely lies in a too sensitive relay, which overheating protection is triggered. There are two options for solving the problem:

  • Temporary
    ... Open the window to reduce the temperature in the room;
  • Radical
    ... The problem can be finally solved only by replacing the relay.

Reason number 4: discharged ignition system batteries

Another reason why the main burner does not light up may be dead batteries. This can be determined by the idle clicks of the piezo ignition element when hot water is turned on.

It is also worth noting that the described problem applies exclusively to water heaters equipped with an automatic switching system.

Reason number 5: insufficiently strong water flow or its complete absence

In order for the gas column to turn on, there must be a pressure of water of a certain strength. If it is too weak, then the unit will not turn on. In this case, you should first clarify the source of the problem by opening the cold water tap in the bathroom:

  • If the water supply level is also weak there
    , means that the matter is in the city water supply system. There is nothing you can do about it, you have to wait;
  • If the liquid runs normally
    most likely, the column itself is clogged.

In the second case, you can call the wizard, or you can try to clean the device yourself. The instruction looks like this:

  1. Shut off the gas supply
    ;
  2. We unscrew the pipes
    ;
  1. We remove the gas water heater from the hinges
    ;
  1. Install it upside down on the table
    ;
  2. Pour a special cleaning liquid inside with a syringe.
    The price of such a mixture is not very high, and you can buy it at any specialized store;
  3. We leave the unit for a couple of hours
    .

Reason # 6: dirty filters

Another reason for the improper operation of the column may be filter clogging. Scale, rust and other insoluble impurities clog the grates over time, and they need to be cleaned. In this case, we are talking not about one object, but about several at once:

PhotoFilter name and location
Water node in the column itself
... In some cases it can be cleaned as described above, in others it will be necessary to disassemble the device and clean the grate manually or completely change it.
Coarse filter
... It is located on the pipe supplying cold water to the water heater.
Mixer filter
.

Reason # 7: membrane deformation

The gas column also does not work in the event of cracks, ruptures or other deformations on the membrane. In this case, it must be replaced.

Rating
( 2 grades, average 5 of 5 )

Heaters

Ovens